Key FeaturesTechnical SpecificationsDownloadsCompare Models
- 500 User Stand-Alone Controller
- Wall Tamper Detection
- 3 User Levels
| OPERATING VOLTAGE RANGE | 12-24 V DC/AC From transformer or power supply |
| MAX. INPUT CURRENT | Standby : 35mA (not including attached devices) Maximum : 8 mA (not including attached devices) |
| INPUTS | REX : N.O., dry relay contacts Auxiliary : In monitor mode, N.C., dry contact Auxiliary : In input mode, N.O., dry contact |
| RELAY OUTPUTS | Lock strike relay : 2 A, form-C with built-in suppressor protection Auxiliary relay : Form C, 1A |
| LED SIGNALING | Two Tri-colored LEDs |
| DIMENSIONS | 92 (H) x 92 (W) x 24 (D) mm (3.5 x 3.5 x 0.945 in) |
| WEIGHT | 130 g (4.6 oz.) |
| OPERATING TEMPERATURE | 0˚C to 63˚C (32˚F to 145˚F) |
| OPERATING HUMIDITY | 0% to 95% relative humidity (non-condensing) |
| OPERATING ENVIRONMENT | Indoor use |
| RFI PROTECTION | > 20 V/m up to 1000 MHz |
| SA1DK Indoor Single-Door Standalone Controller
|
SA1DP Indoor Single-Door Standalone Pin & Proximity Controller
|